Related Links
Oil and Gas products overview... Facility controller... Flowing well controller products overview... Pump off controller products overview... Water alternate gas injection controller products overview... Bailey WAG... WAGTM... User's manual (3.6 MB) [Access controlled]... LP_WAGTM... WAG350TM... WIC-IITM... WFMTM...| Mechanical | Enclosure: 18" x 16" x 8" NEMA 4X Enclosure |
| Environmental | Operating temperature: -40 to 158 deg. F (-40 to 70 deg. C) |
| Relative humidity: 5 to 95% non-condensing | |
| Power requirements | 12 or 24 VDC, 110 VAC and custom power supplies available. |
| CPU / Memory | CPU: 16-bit CMOS micro-controller and co-processor, 14.74 MHz clock |
| Watchdog timer: Integrated | |
| Memory: 1 MB CMOS RAM, 512 kB flash ROM, 1 kB EEPROM | |
| Communications ports | 1 each wireless Bluetooth local operator interface standard |
| 1 each RS-232 Communications: wireline modems, licensed frequency, spread spectrum, and wireless ethernet supported (19,200 baud maximum) | |
| 1 each RS-232 / RS-485 port: 4102MMT / 3095MMT multivariable flowmeter | |
| Optional RS-232 cable |
| Pulse input | Turbine meter |
| Analog inputs | Tubing temperature |
| Header pressure | |
| Tubing pressure | |
| Casing pressure | |
| Differential pressure | |
| Battery Voltage | |
| Digital input / output | Reset |
| Choke open | |
| Choke closed | |
| Computer / local | |
| Two spare | |
| Relay output | Actuator direction |
| Actuator pulse |